Rotax 915 i A series Maintenance Manual page 458

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 20.18
Exhaust pipe cyl. 2
1
Exhaust pipe clamp
3
5
Allen screw M5x10
FINISHING WORK
ATTENTION
Follow the aircraft manufacturer's instructions
for installation.
See Chapter 76-70-00 section
ture sensor (EGT1/EGT2/EGT3/EGT4) —
installation.
Step
Procedure
1
Install the temperature sensor (EGT) into
the exhaust pipe, lubricate with LOCTITE
ANTI SEIZE.
NOTE
Do not forget the sealing ring.
2
Tighten the temperature sensor to 15 Nm
(133 in. lb.).
78–10–00
Page 12
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Exhaust pipe cyl. 4
2
4
Lock nut M5
Exhaust gas tempera-
Figure 20.19
Exhaust pipe
1
Sealing ring
3
Temperature sensor
2
(EGT)
Effectivity: 915 i A Series