COOLING AIR-DUCT (OPTIONAL) —
REMOVAL
Procedure
Step
1
Remove fuel inlet and outlet hoses.
2
Remove intake manifolds, airbox and
cooling expansion tank assy.
3
Lift up and remove cooling air-duct.
WATER PUMP HOUSING — REMOVAL
Preparation
Remove the coolant hose from water inlet
elbow according to the aircraft manufactur-
er's specifications.
NOTE
Mark the position of the coolant elbow with a
suitable pen (touch-up pen).
Step
Procedure
1
Remove the coolant hoses with heat pro-
tection sleeves from coolant elbow using
spring clamp pliers part no. 877840.
75–00–00
Page 12
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Figure 14.10
1
Bent socket
3
Coolant hose
Step
Procedure
2
Remove all 4 spring type hose clamps us-
ing spring clamp pliers part no. 877840
and detach the coolant hoses from the
water pump housing.
Spring type hose clamp
2
25
Heat protection tube
4
Effectivity: 915 i A Series