Figure 4.13
Connector regulator A
1
Figure 4.14
1
Connection socket
Step
Procedure
4
Remove the two round connectors (la-
belled Lane A, Lane B) of the fuse box.
NOTE
Loosen the connector cap nut coun-
ter-clockwise.
5
Pull the connectors in the two grooves
out of the connector socket.
71–00–00
Page 20
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Connector regulator B
2
2
Connector regulator
Figure 4.15
NOTE
Round connectors have different grooves and
cannot be mixed.
Fuel pump
See Chapter
73–10–00 section Fuel pump assy. –
removal.
Control unit (ECU)
ATTENTION
ECU connectors are limited to 20 mating
cycles.
Coupler removal must be logged on label.
See
Chapter 76–10–00 section Control unit
Step
Procedure
1
Press in the lock so that the clamp can be
rotated.
2
Press the clamp down until it latches.
(ECU).
Effectivity: 915 i A Series
Edition 0/Rev. 0