Step
Procedure
1
Tighten crankshaft position sensors using
hex. screws M6x20 with lock washers
and secure with LOCTITE 243. Tighten-
ing torque 10 Nm (89 in. lb.)
ATTENTION
Arrange the cable so that it does not rest
against the engine suspension frame or other
components.
Figure 18.54
Crankshaft position
1
sensor CPS_1
Cable clamp
3
5
Hex. screw M6x50
7
Hex. screw M6x20
76–70–00
Page 32
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Crankshaft position
2
sensor CPS_2
4
Washer
6
Lock washer
8
O-ring
Step
Procedure
2
Push the cable clamp onto the cables
and tighten with hex. screw M6x50 and
washer with LOCTITE 243 to the ignition
housing. Tightening torque 10 Nm (89 in.
lb.)
3
Plug the respective wiring harness con-
nector into the crankshaft position sensor.
4
Carefully push the connector (CPS) into
the locking plate. Secure the connectors
with a cable tie.
Figure 18.55: TYPICAL
Connector (CPS)
1
3
Cable tie
THROTTLE POTENTIOMETER (TPS) —
INSTALLATION
Step
Procedure
1
Install the throttle body assy. To do this,
see
Chapter 73-10-00 section Fuel
2
Plug the respective wiring harness con-
nector into the throttle potentiometer.
Locking plate
2
pump.