NOTE
When using a heat transfer pad, no additional
application of a thermal compound is required.
Figure 16.10
Heat transfer pad
1
ATTENTION
The regulator must be mounted so that it does
not project beyond the regulator plate.
Step
Procedure
3
Fasten regulator to the fuse box with 2
lock nuts M6 and washers. Tightening tor-
que: 6 Nm (53 in.lb). Wrench size: A/F
10.
NOTE
Tighten the two lock nuts M6 alternately to en-
sure a smooth seat of rectifier regulator on the
regulator plate.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Regulator
2
Figure 16.11
Regulator B
1
3
Lock nuts M6
Step
Procedure
4
Remove the connecting thread of sealing
union of the rectifier regulator that should
be mounted.
NOTE
The connecting thread of sealing union is in-
cluded with each rectifier regulator as replace-
ment part. An exchange of this plastic insert is
only necessary if it is damaged.
2
Washer 6.4
76–20–00