Figure 14.38
1
Bent sockets
3
Coolant hoses
Figure 14.39
1
Bent socket
3
Coolant hose
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Hose clamps
2
Heat protection
4
sleeves
Spring type hose clamp
2
25
4
Heat protection sleeve
COOLING AIR-DUCT (OPTIONAL) —
INSTALLATION
Procedure
Step
1
Attach cooling air duct (is not mechani-
cally held in place).
2
Install intake manifold, airbox and cooling
expansion tank assy.
EXPANSION TANK AND COOLANT
HOSE — INSTALLATION
ATTENTION
Ensure that the expansion tank is fixed without
tension.
NOTE
Check the push-on lengths, readjust the pre-
formed hoses if necessary.
Step
Procedure
1
Install coolant elbows 1 to 4. See
72-30-00 section Cylinder
2
Mount 1 spring type hose clamp 35 on
the preformed hose radiator outlet and
mount 1 spring type hose clamp 25 each
on preformed hoses 1, 2, 3, and 4.
3
Position the expansion tank assy. with the
5 preformed hoses on the engine.
Chapter
head.
75–00–00
Page 27