Rotax 915 i A series Maintenance Manual page 311

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Step
Procedure
2
Carefully pull EGT 1 and EGT 2 (cylinders
1 and 2) out of the locking plate.
3
Press the spring and unplug the
connectors.
Figure 13.6
1
EGT connector
Step
Procedure
4
Loosen Allen screws M5x16 with lock
washers A5.
Figure 13.7
1
Allen screw M5x16
3
Cable holder
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
2
Connector bracket
2
Lock washerA5
Step
Procedure
5
Remove the connectors to the double
ignition coils.
6
Remove the double ignition coils
Figure 13.8
Double ignition coils
1
NOTE
The red cable is positive (+), the black cable is
negative (-). Double ignition coils are labelled +
and -!
SPARK PLUG CONNECTOR AND
IGNITION CABLE ASSY. — REMOVAL
Procedure
Step
1
Remove cable ties.
2
Unscrew the spark plug connector.
3
Unscrew ignition cable from ignition coils.
NOTE
The rubber seal may need to be pulled back off
the coil in order to unscrew the cable.
Ignition coil connector
2
(coil 1, coil 2, coil 3, coil
4)
74–20–00
Page 9
August 01 2018

Advertisement

Table of Contents
loading