Removal; Ignition Housing - Removal - Rotax 915 i A series Maintenance Manual

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

REMOVAL

Preparation
ATTENTION
Use appropriate protective coverings to prevent
the ingress of foreign bodies into connected lines
and connections.
Drain coolant. See Maintenance Manual
Line for the engine type 915 i A Series.
• Remove adjacent assemblies (electric starter,
water pump).
• Remove coolant hoses from cylinder head.
• Remove CPS - crankshaft position sensors (rev
counter assy.) To do this, see
section Sensors and
NOTE
The assemblies and lines are only to be re-
moved if necessary and only as far as is
necessary!
IGNITION HOUSING – REMOVAL
Step
Procedure
1
Detach the electrical connection to the
stator by disconnecting the controller con-
nector. Mark before detaching!
2
Press on the catch and disconnect the
connector.
Effectivity: 915 i A Series
Edition 0/Rev. 0
MAINTENANCE MANUAL HEAVY
Chapter 76-70-00
actuators.
BRP-Rotax
Figure 2.4
1
Controller connector
Step
Procedure
3
Loosen the airbox bracket. Loosen the
lock nut and remove it along with the
washer.
Figure 2.5
1
Washer A 6.4
Rubber buffer
3
20x10xM6
NOTE
Push airbox upwards and wedge in place.
Step
Procedure
4
Loosen 2 Allen screws M5x45 and hex.
nuts M5 on electric starter.
2
Connection socket
2
Lock. nut M6
24–20–00
Page 7
August 01 2018

Advertisement

Table of Contents
loading

Table of Contents