REMOVAL
Preparation
ATTENTION
Use appropriate protective coverings to prevent
the ingress of foreign bodies into connected lines
and connections.
Drain coolant. See Maintenance Manual
Line for the engine type 915 i A Series.
• Remove adjacent assemblies (electric starter,
water pump).
• Remove coolant hoses from cylinder head.
• Remove CPS - crankshaft position sensors (rev
counter assy.) To do this, see
section Sensors and
NOTE
The assemblies and lines are only to be re-
moved if necessary and only as far as is
necessary!
IGNITION HOUSING – REMOVAL
Step
Procedure
1
Detach the electrical connection to the
stator by disconnecting the controller con-
nector. Mark before detaching!
2
Press on the catch and disconnect the
connector.
Effectivity: 915 i A Series
Edition 0/Rev. 0
MAINTENANCE MANUAL HEAVY
Chapter 76-70-00
actuators.
BRP-Rotax
Figure 2.4
1
Controller connector
Step
Procedure
3
Loosen the airbox bracket. Loosen the
lock nut and remove it along with the
washer.
Figure 2.5
1
Washer A 6.4
Rubber buffer
3
20x10xM6
NOTE
Push airbox upwards and wedge in place.
Step
Procedure
4
Loosen 2 Allen screws M5x45 and hex.
nuts M5 on electric starter.
2
Connection socket
2
Lock. nut M6
24–20–00
Page 7
August 01 2018