Thread locker for
pre-assembled parts
Thread locker application for pre-assembled parts.
Figure 1.8: Application for pre-assembled parts
Step
NOTE
For preventive maintenance on existing equipment, retighten nuts and apply prop-
er strength LOCTITE on bolt/nut contact surfaces.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
2
Apply here
1
Procedure
1
Clean bolts and nuts with solvent.
2
Assemble components.
3
Tighten nuts.
4
Apply a few drops of proper strength LOCTITE on bolt/nut contact surfaces.
5
Avoid touching metal with tip of flask.