Step
Procedure
3
Install puller assy. part no. 876010 on
ignition housing. Apply a thin coating of
LOCTITE 5910 the sealing surface of the
ignition housing. Install protective mush-
room into crank shaft.
Figure 2.40
Ignition housing
1
m WARNING
Danger of injury!The magnet of the fly wheel
pulls the ignition cover towards the engine/
sealing surface with high force.Fingers can be
crushed.
Make sure screw of puller assy. is rotated inwards
so the ignition cover is not pulled towards the
engine.
Step
Procedure
4
Install ignition housing on the crankcase
with puller assy. part no. 876010.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Figure 2.41
Ignition housing
1
3
Protection mushroom
Procedure
Step
5
Turn the water pump wheel slightly so
that the gear wheels can match.
6
Fasten the ignition housing to the crank-
case using Allen screws.
Tightening torque 10 Nm (89 in. lb.).
Puller assy. part no.
2
876010
24–20–00
Page 21