Rotax 915 i A series Maintenance Manual page 362

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 15.10: B.U.D.S. Aircraft Start
Step
Procedure
2
Wait until the program has been started
completely.
3
Check if both Lane Health Indicators (top-
left corner) turn green. If they are gray
check connections and power supply
and/or restart B.U.D.S. Aircraft.
4
Change to "ECU configuration" tab.
76–10–00
Page 12
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Figure 15.11: ECU configuration tab
Step
Procedure
5
Read and note the values of following
fields:
• Software P/N: This value indicates the
current software installed on the ECU.
NOTE
Knowing the current "Software Con-
fig. Part Number" and "ECU part num-
ber" is crucial, when loading ECU
software or verifying if ECU has the
latest software installed.
6
Disconnect the wiring attached to connect
the ECU with the computer.
• Disconnect power supply of the Service
Wiring Harness.
• Disconnect B.U.D.S. Aircraft Set
• Disconnect Service Wiring Harness
connectors
Effectivity: 915 i A Series
Edition 0/Rev. 0