Rotax 915 i A series Maintenance Manual page 400

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 17.21
1
Pressure sensor
CRANKSHAFT POSITION SENSOR —
DISCONNECTION
Wiring harness designation:
• CPS_1 for LANE A (yellow mark)
• CPS_2 for LANE B
Step
Procedure
1
Remove cable ties.
2
Unplug CPS 1 and CPS 2.
76–50–00
Page 16
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
2
Cable ties
Figure 17.22
1
KNOCK knock sensor
CPS_2 LANE B
3
5
Cable tie 203x7.6
KNOCK SENSOR — DISCONNECTION
Wiring harness designation:
• KNOCK
Procedure
Step
1
Lift the latch and pull apart.
AIRBOX PRESSURE SENSOR AND
TEMPERATURE SENSOR —
DISCONNECTION
Wiring harness designation:
• MAPS_1 and MATS_1 for LANE A
• MAPS_2 and MATS_2 for LANE B
Step
Procedure
1
Remove the 2 cable ties and 2 clamps.
2
Unplug the connectors of the 2 pressure
sensors.
3
Lift the latch and pull off.
2
CPS_1 LANE A
4
Cable tie
Effectivity: 915 i A Series