Rotax 915 i A series Maintenance Manual page 382

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Arrangement of the fuses
F12
5 A Injector 2
F13
5 A Injector 1
F14
2 A Caution lamp A
F15
2 A Caution lamp B
F16
5 A Injector 8
F17
5 A Injector 7
F18
5 A Start switch
F19
Not used
F20
20 A Lane A circuit
F21
35 A Lane B circuit
F22
5 A Injector 6
F23
5 A Injector 5
Figure 16.18
1
Reserve fuses
76–20–00
Page 14
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
ATTACHMENT OF COVER
ATTENTION
Over tightening the hex screws M4 leads to
cracking of the cover.
Step
Procedure
1
Fix cover with 9 hex screws M4 finger-
tight. Snug with hex key A/F 3 mm.
NOTE
Before attaching the cover, check the correct
position of the gasket.
INSPECTION OF INSTALLATION OF THE
REGULATOR
Before installing the fuse box carry out a continuity
check using a multimeter between the regulator
housing and regulator A and regulator B. A conduc-
tive connection (continuity) must not be present.
ATTENTION
If a conductive connection (continuity) is
present, the installation of the regulator has to
be checked. The fuse box must not be installed
in an aircraft until the error is fixed and the in-
stallation corrected.
Figure 16.19
1
Multimeter
Regulator B (grey
3
wire connector)
Regulator A (black wire
2
connector)
Effectivity: 915 i A Series
Edition 0/Rev. 0

Advertisement