Rotax 915 i A series Maintenance Manual page 381

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 16.16
Regulator A
1
Connection bolt regu-
3
lator A
ATTENTION
The ring terminals attached to the connecting
ports A-, A and A+ must not touch each other
(except those rings which are attached to the
same connection bolt).
Step
Procedure
6
Connect the unlabeled cable ends com-
ing out of the fuse box and the regulator
(2 pcs. BLACK) with the regulator plate.
Positioning of the cables must be as
shown in following figure.
Fasten the cable lug with locking nut M4
and washer on the connection bolt. Tight-
ening torque: 1,2 Nm (11 in.lb). Wrench
size: A/F 7.
7
Fasten gasket screw connection. Tighten-
ing torque: 4 Nm (35 in.lb). Wrench size:
A/F 25.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Regulator B
2
Connection bolt regula-
4
tor B
Figure 16.17
1
Cable BLACK
3
Washer 6.4
Cap nut of the bulk-
5
head fitting
FUSES
If a fuse is damaged, it must be replaced by a new
one with the same values.
m WARNING
A fuse with a higher amperage must not be
used, as this can lead to severe damage.
Arrangement of the fuses
F2
7.5 A Selector switch B
F3
7.5 A Selector switch A
F4
10 A Fuel pump B
F5
10 A Fuel pump A
F6
10 A Ignition 3t
F7
10 A Ignition 1b
F8
10 A Ignition 3b
F9
10 A Ignition 1t
F10
5 A Injector 4
F11
5 A Injector 3
2
Cable BLACK
4
Lock nut M6
76–20–00
Page 13
August 01 2018

Advertisement

Table of Contents
loading