DISASSEMBLY
IGNITION HOUSING — DISASSEMBLY
Preparation
• Remove the ignition housing. See
00 section Internal
generator.
WATER PUMP SHAFT — REMOVAL
Step
Procedure
1
Place the ignition cover on a suitable flat
surface.
2
Press out the water pump shaft with a
suitable tool.
3
Pull out the water pump gear.
Figure 14.15
1
Press-out tool
Water pump shaft
3
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Chapter 24-20-
2
Water pump gear 15T
OIL SEAL AND ROTARY SEAL —
REMOVAL
ATTENTION
The oil seal and rotary seal are destroyed by
this process and must be replaced.
Step
Procedure
1
Press out the old oil seal and the rotary
seal with two pins or bolts and a suitable
jig.
NOTE
The diameter of the pins/bolt is 5 mm (0.1969
in.).
Figure 14.16
1
Oil seal
3
Press-out tool
COOLANT HOSES — REMOVAL
Step
Procedure
1
Take off the spring type hose clamps us-
ing spring clamp pliers part no. 877840.
2
Remove the preformed hoses from the
coolant elbows on the expansion tank
with a suitable tool.
3
Remove the rubber plate.
2
Rotary seal
75–00–00
Page 15