Rotax 915 i A series Maintenance Manual page 340

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 14.27
Water pump housing
1
3
45° bent socket
COOLANT HOSE — INSTALLATION
ATTENTION
The push-on length of the expansion tank is 25
mm (0.9843 in.)!
ATTENTION
Hoses must not be shortened!
NOTE
The hoses are all preformed and cut to length in
the factory, and the hose length and push-on
length therefore defines the position of the ex-
pansion tank. The correct position of the expan-
sion tank ensures trouble-free installation of the
governor.
NOTE
Mark the push-on lengths of the hoses on the
water elbows.
Procedure
Step
1
Install a new rubber plate on preformed
hose connection 2, 4 and 1.
75–00–00
Page 22
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
2
20° bent socket
Figure 14.28
Preformed hose con-
1
nection 1
Rubber plate
3
Step
Procedure
2
Install the spring type hose clamp 35 on
the preformed hose radiator outlet.
3
Push on the preformed hose radiator out-
let and align it vertically.
NOTE
Align the spring type hose clamp 35 vertically as
well, so that the remaining coolant hoses can be
installed.
Preformed hose con-
2
nection 2
Preformed hose con-
4
nection 4
Effectivity: 915 i A Series