Rotax 915 i A series Maintenance Manual page 376

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

INSTALLATION
• The regulator is installed and removed in the same
way. The following should be noted.
NOTE
If the wire is broken or the connector is defec-
tive, the damage can be repaired. The cable
must be long enough if the connector is cut off.
Repair with the tools described here must com-
ply with the aircraft standard of the respective
country.
Part no. from the Connector
Set
866420
866422
Figure 16.8
Regulator A
1
76–20–00
Page 8
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Associated Tool
DEUTSCH HDT-
48 - 00
DEUTSCH connector
2
(black)
Figure 16.9
Regulator B
1
ATTENTION
All hex nuts (self-locking) must be replaced
after each installation (e.g. replacement of a
regulator).
REGULATOR B — INSTALLATION
ATTENTION
The adhesive surface on the back of the regu-
lator must be cleaned before applying the heat
transfer pads. Remove the protective film with
caution, because rapid stripping can damage
the heat transfer pad.
Step
Procedure
1
Clean the regulator plate: Remove resi-
dues of the thermal paste or the heat
transfer pads.
2
Bonding the heat transfer pad to the recti-
fier regulator: Remove the protective film
from heat transfer pad and stick the heat
transfer pad with the adhesive surface
onto the rectifier regulator (avoid any
folds or bubbles). The positioning has to
be done as shown in following Figure.
DEUTSCH connector
2
(grey)
Effectivity: 915 i A Series
Edition 0/Rev. 0