Figure 16.13: Connection
Regulator A
1
Connection bolt regu-
3
lator A
ATTENTION
The ring terminals attached to the connecting
ports B-, B and B+ must not touch each other
(except those rings which are attached to the
same connection bolt).
Step
Procedure
9
Connect the unlabeled cable ends com-
ing out of the fuse box and the regulator
(2 pcs. BLACK) with the regulator plate.
Positioning of the cables must be as
shown in Figure Connection
Fasten the cable lug with locking nut M4
and washer on the connection bolt. Tight-
ening torque: 1,2 Nm (11 in.lb). Wrench
size: A/F 7.
10
Fasten gasket screw connection. Tighten-
ing torque: 6 Nm (53 in.lb). Wrench size:
A/F 30.
11
Install the Regulator connector into the
connector bracket assy.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Regulator B
2
Connection bolt regula-
4
tor B
Figure 16.14
1
Cable BLACK
3
Lock nut M4
REGULATOR A — INSTALLATION
The regulator A is installed in the same way to
lator B (Step 1 up to Step
ATTENTION
Note the wire marking and labeling of the con-
necting bolts (labeled on the board of the fuse
Step
Procedure
1
Remove the connecting thread of sealing
union of the rectifier regulator that should
be mounted.
NOTE
The connecting thread of sealing union is in-
cluded with each rectifier regulator as replace-
ment part. An exchange of this plastic insert is
only necessary if it is damaged.
2
Washer 4.3
Cap nut of the gasket
4
screw connection
regu-
3). To be observed.
box).
76–20–00
Page 11
August 01 2018