Figure 14.17
Expansion tank
1
3
Preformed hoses
WATER PUMP HOUSING —
DISASSEMBLY
NOTE
Only remove the bent sockets when absolutely
necessary!
Step
Procedure
1
Mark the position of the bent sockets.
2
Heat the water pump housing to approx.
80 °C (176 °F) and unscrew the bent
sockets.
3
Clean the thread (remove LOCTITE resi-
dues) inside the housing and on bent
socket.
75–00–00
Page 16
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
2
Rubber plate
Spring type hose
4
clamps
Figure 14.18
Water pump housing
1
3
Thread
2
Bent socket