Rotax 915 i A series Maintenance Manual page 435

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 18.40
Boost pressure sen-
1
sor (BPS)
MANIFOLD PRESSURE SENSOR
(MAPS_1/MAPS_2) — INSTALLATION
Procedure
Step
1
Clean the thread of the manifold pressure
sensor.
2
Tighten MAPS with an 21 mm socket
wrench part no. 876075 (or similar tool).
Tightening torque 10 Nm (89 in. lb.).
3
Plug the respective wiring harness con-
nector into the corresponding pressure
sensor. See
Chapter 76-50-00 section
Wiring harness (main
4
Make sure to put the connector latch to
the bottom.
5
Install the clamp. Check for tight fit and
correct position of the clamp on sensor
and connector!
6
Attach cable ties (strain relief) .
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
strand).
Figure 18.41: Position of the clamp
Clamp
1
Figure 18.42
Pressure sensors
1
(MAPS_1/MAPS_2)
3
Cable ties
PRESSURE CONTROL VALVE –
INSTALLATION
NOTE
For installation of the hoses, see Chapter 73-10-
00 section
Pressure control valve hoses -
installation.
Manifold pressure sen-
sors (MAPS_1/MAPS_
2
2)
2
Clamp
76–70–00