NTP-003
: System Turnup
Page 2 of 6
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
NOTE:
If the DDM-2000 fails to respond in the indicated manner,
refer to Trouble Clearing: IXL-001.
Verify that no LEDs or alarms are activated. If any LEDs or alarms
are activated, refer to Trouble Clearing: IXL-001 and follow the
appropriate trouble-clearing procedure.
2.
NOTE:
The rtrv-eqpt: command retrieves the Equipage and
Version Report. This report lists the circuit pack type
and version information for one or more slots. See the
Commands and Reports section of this manual for a
description of the rtrv-eqpt: command format.
At each DDM-2000 OC-3 terminating end, use the rtrv-eqpt:
command to obtain the Equipage and Version Report and
verify that the proper service and protection (if required) MXRVO
(STS1E) circuit packs have been installed in FUNCTION UNITS
group(s) (A, B, or C) being put into service.
3.
At the HDSL terminating node(s) of the circuit being established,
determine which HDSL port(s) is to be put into service and what
options are to be selected.
4.
NOTE:
Both service and protection MXRVO circuit packs must be
installed in group equipped with HDSL circuit packs.
At each HDSL terminating node, set option switches and install
HDSL circuit pack(s), as required.
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285
DLP-564