NTP-052
: Circuit Order
Page 5 of 6
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
11.
!
CAUTION:
No service LOW SPEED slots should be left empty.
Install 177A Retainer Card(s), as required, into the LOW SPEED
slot(s) for the T1EXT circuit pack(s) removed.
12.
NOTE:
If a port is in the nmon (n) state, the signal is not monitored
or alarmed. The port will not automatically go to the in
service (i) state when a signal is detected as it will in the
auto (a) state. In the nmon state, the port must be returned
to the auto state, using the set-state-t1: command, to
turn on monitoring of signal failures and before any circuit
packs associated with that port can be removed from the
equipment list by the upd command.
If circuit packs have been removed, momentarily depress the
UPD/INIT button on the SYSCTL or use the upd command to
update the DDM-2000 internal equipment list.
If circuit packs have not been removed, use the set-state-t1:
command to set the port state of the DS1 port(s) to auto or
nmon, as required.
13. Verify all alarms are off.
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER