Lucent DDM-2000 OC-3 User And Service Manual page 858

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
/* Neighbor Map for Site6NE1
=================================================================
TID
NSAP
=================================================================
Site6NE1
39 840F 80 000000 0000 0000 0000 08006alad06e 00
Site7NE1
39 840F 80 000000 0000 0000 0000 08006alad06f 00
Site5NE1
39 840F 80 000000 0000 0000 0000 00000e3a0372 00
*/
Figure 8 – Sample Report From rtrv-map-neighbor Command (R15)
18. After all connections and tests have been made, verify optical fiber cables are
placed correctly in fiber tray/rings and properly routed in bay framework.
Reinstall front cover and tighten three screws.
19. Repeat this procedure for each fiber span to be connected until the end-to-end
system is established.
20. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
Detailed Level Procedure:
Connected Thru
Product Type
DDM-2000 OC-3
main-1
main-2
DDM-2000 OC-3 M
Level 2 IS
Y
ULTIPLEXER
DLP-514
Page 18 of 18