Lucent DDM-2000 OC-3 User And Service Manual page 535

Tarp release 13 and later volume ii
Table of Contents

Advertisement

NTP-056
: System Turnup
Page 5 of 12
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
11.
NOTE:
If Sync Autoreconfiguration is enabled, Kbyte/Sbyte must
also be enabled.
NOTE:
If Sync Autoreconfiguration is enabled at any line-timed
OC-3 node in a ring, it must be enabled at all line-timed
OC-3 nodes of a ring.
NOTE:
The rtrv-sync: command retrieves the
Synchronization
provisioning and operational information on the
synchronization attributes of the DDM-2000. See the
Commands and Reports section of 363-206-295, DDM-2000
OC-12 Multiplexer, TARP Release 7, User/Service Manual—
Volume I or 363-206-285, DDM-2000 OC-3 Multiplexer,
TARP Release 13 and Later, User/Service Manual—Volume
I for a description of the rtrv-sync: command format.
Use the rtrv-sync: command to obtain the
Synchronization Report and verify if Sync
Autoreconfiguration is enabled or disabled. Use the set-sync:
command to enable or disable the Sync Autoreconfiguration
parameter, as required.
12.
NOTE:
Two or more shelves in the same network cannot have the
same system name or TID (set by the set-ne: command).
Verify no duplicate TID settings exist. The rtrv-ne: command
may be used at each shelf in the network to display settings. If
duplicates exist, determine new settings and use the set-ne
command to make new settings.
Report. This report displays the
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285