363-206-285
Issue 2, February 2000
5.
Observe one of the following indications on the FE ID display. Note the
indication and follow the suggested procedure.
A.
Letter "P" in FE ID Display
Indicates no software installed in SYSCTL. Software must be downloaded
locally using these procedures.
Continue with Step 6.
B.
Letter "P." in FE ID Display
Indicates corrupted application software. New software must be force
downloaded locally using these procedures.
Proceed to Step 19.
C. FE ID Display Blank:
Indicates compatible software is installed in OHCTL and SYSCTL. This
procedure assumes the installed software version is not the correct
version. (Depress ACO button for longer than 2 seconds to display
software version on the FE ID display.)
Proceed to Step 9.
D. Letter "d" in FE ID Display:
Indicates OHCTL has no software or that software in OHCTL and
SYSCTL is incompatible.
Proceed to Step 19.
E.
Letter "C" in FE ID Display:
Indicates software is installed in OHCTL and SYSCTL, but it will not
support the current shelf provisioning.
Proceed to Step 23.
DDM-2000 OC-3 M
Detailed Level Procedure:
ULTIPLEXER
DLP-532
Page 4 of 14