12. If the BBF2B/BBF2C TGS or BBF4 TG3 is provisioned for sync out mode ,
refer to Table H and Figure 3 and set equalizer switches for the proper cable
length.
Table G – Equalizer Switch Settings
Equalization
0' to 131'
>131' to 262'
>262' to 393'
>393' to 524'
>524' to 655'
Invalid*
Invalid*
Invalid*
*
If an invalid setting is selected, FAULT LED
is lighted and an alarm is generated
(unexpected CP type or
unexpected CP switches).
13.
NOTE:
Switches S1-1 and S1-2 are ignored by the system the first time the
TGS/TG3 is installed unless the timing mode is set to DS1 External or
Line Timing sync out mode . Subsequent removal or replacement of the
TGS/TG3 requires that switches S1-1 and S1-2 be set the same as the
original settings or an update (upd) command must be performed.
Is timing mode set to either DS1 External or Line Timed sync out ?
If YES, then continue with Step 14.
If NO, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
14. Refer to Table H and Figure 3 and set the DS1 line coding and frame format as
required for the TGS/TG3 circuit pack.
Table H – BBF2B/BBF2C TGS/BBF4 TG3 DS1 Line Coding and Frame Format
Switch Settings
DS1 Line Code
AMI
B8ZS
15. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
S2-1
S2-2
S2-3
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Switch
S1-1
DS1 Frame Format
ON
SF
OFF
ESF
DDM-2000 OC-3 M
Detailed Level Procedure:
Switch
S1-2
ON
OFF
ULTIPLEXER
DLP-513
Page 11 of 20