Lucent DDM-2000 OC-3 User And Service Manual page 650

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
Table B – RTRV-ALM Message Descriptions (Continued)
Description
controln
CP not allowed - (crs)
CP not allowed - (eqpt)
CP not allowed - (timing)
CP removed
dormant/executing code mismatch
DS1 CP failed
Alarm
Level
Status
CR or MN The circuit pack does not support the manual
MJ or MN
CR or MN When associated with a TIMING slot, the current
CR, MJ or
MN
Status
MJ or MN
DDM-2000 OC-3 M
Trouble Clearing:
Meaning
The specified environmental control point
(miscellaneous discrete output) is active. Note:
The actual message that appears in the Active
Alarms and Status Report for this condition
can be provisioned; this is the default message.
(See the rtrv-attr-cont: and
set-attr-cont: commands.)
Likely cause: The system was instructed to close
the environmental control point by either a TBOS
control point or by the closing of the corresponding
environmental control input at the far end.
cross-connection(s) currently provisioned for this
slot. The user should change the circuit pack type
or change the cross-connection(s) to the slot.
A DS1 or DS1PM circuit pack is installed in a LOW
SPEED slot associated with a FUNCTION UNITS
slot currently provisioned for DS3, STS1E_L (low
speed), or OLIU circuit pack service. The DS1 or
DS1PM circuit pack should be removed from the
shelf, or the FUNCTION UNITS circuit pack should
be replaced with an MXRVO or STS1E_H (high
speed) circuit pack.
circuit pack switch settings do not support the
synchronization timing provisioned. The user
should change the circuit pack switches or change
the settable synchronization parameters.
When associated with FUNCTION UNITS slot C,
the circuit pack type does not support the current
provisioned synchronization parameters. The
circuit pack type or the timing options should be
changed.
A circuit pack previously installed in this system is
removed. The circuit pack should be replaced, or
an update (upd) command should be done to
remove it from the system equipment list.
This alarm condition is raised when the network
element (NE) detects that dormant software exists
on the NE with a release number that does not
match the release number of the executing
software.
Internal equipment failure of the specified DS1
circuit pack.
ULTIPLEXER
TAP-107
Page 6 of 28