Lucent DDM-2000 OC-3 User And Service Manual page 790

Tarp release 13 and later volume ii
Table of Contents

Advertisement

DLP-508
: Detailed Level Procedure
Page 2 of 4
3.
NOTE:
DS1 line coding may be set using either the option switches OR the
set-t1 command. It is recommended that a policy be established to set
line coding using either the switches OR the command. If DS1 line code
(lc) parameters are set using the set-t1 command, a software override
will be active and the circuit pack switch settings will have no effect. The
software override will remain active until the set-t1 command is
executed again and the noOverride option is selected. The rtrv-t1
command may be used to check line code settings.
Refer to Table B and Figure 1 and set the line code option switches, if required.
Table B – DS1/DS1PM Line Code Settings
Switch S1 Settings
Line Code
S1-4
Format
(Port 1)
B8ZS
OFF
AMI
ON
Note: Switch 1, section 8 (S1-8) is unused and ignored by the system.
4.
NOTE:
If the response is not correct when the DS1/DS1PM circuit pack is
installed, check option switch setting. If settings are correct, replace the
DS1/DS1PM circuit pack.
Seat DS1/DS1PM circuit pack in required slot of LOW SPEED group being
equipped.
Response:
S1-5
S1-6
(Port 2)
(Port 3)
OFF
OFF
ON
ON
Figure 1 – DS1/DS1PM Option Settings
FAULT LED on DS1/DS1PM circuit pack lights and may
remain lighted for about 40 seconds and then goes off.
DDM-2000 OC-3 M
Issue 2, February 2000
S1-7
S1-8
(Port 4)
(Note)
OFF
OFF
ON
ULTIPLEXER