NTP-004
: Acceptance
Page 2 of 6
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
2.
!
CAUTION:
The init-sys:all command should NOT be used on an
in-service system.
NOTE:
During installation and/or initial testing, provisionable
parameters may have been set which need to be reset to
default values. STS-1 and/or VT1.5 (DS1) cross-connections
may have been made which should be deleted before the
system is placed in service. The init-sys:all command
will reset all provisionable parameters and
cross-connections to default values. If parameters have
already been set to their proper values and you are sure they
are set correctly, you may not want to perform this step.
Some parameters will have to be reset later before service is
established.
NOTE:
An inconsistent DCC values alarm will occur when the
init-sys:all command is executed, if fecom has not
been enabled at both ends of the system.
If required, use the command init-sys:all to reset
provisionable parameters to default values.
DDM-2000 OC-3 M
Issue 3, June 2001
ULTIPLEXER
363-206-285