Lucent DDM-2000 OC-3 User And Service Manual page 966

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
d.
After the current software is up and running (no alarm LEDs lighted or
you can log into the shelf), reinstall the TGS/TG3 circuit pack in TIM-
ING slot 1.
26. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
27. Did the download start as indicated by the In progress message and rows
of dots?
If NO, then continue with Step 28.
If YES, then proceed to Step 30.
28. Perform the following:
A.
Check that the DDM-2000 is connected to the PC through the COM port.
If it is not, reconnect the PC to DDM-2000 using the COM port and repeat
this procedure.
B.
Ensure first (number 1) disk of program being installed is inserted, if using
floppies.
C. Ensure diskette is inserted in correct drive.
D. Ensure the proper command was used to go to the drive with the diskette
or to the proper directory containing the software.
E.
Check for invalid COM port. Exit TERM (Alt F2), then restart TERM using
term COM1 or term COM2.
F.
If the download still does not start, as indicated by the In progress
message and rows of dots, within 2 minutes after the P appears in the FE
ID display, change the baud rate as follows and repeat this procedure: if
the baud rate is currently set to 9600, change it to 4800 or if the baud rate
is currently set to 4800, change it to 9600. The baud rate is changed by:
1.
Momentarily depress the Alt C keys.
2.
Use the RETURN key to move to the "Speed" field.
3.
Press the "Space" bar until the desired rate appears.
4.
Momentarily depress the Esc(Escape) key to activate the new
baud rate.
G.
If the download still does not start, refer to Trouble Clearing: TAP-116.
29. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
DDM-2000 OC-3 M
Detailed Level Procedure:
ULTIPLEXER
DLP-532
Page 12 of 14