DLP-532
: Detailed Level Procedure
Page 9 of 14
15. Was response correct?
If YES, then continue with Step 16.
If NO, then do Trouble Clearing: TAP-116.
16. Enter a y or yes and a carriage return to execute the program. Software
download may take 20 to 45 minutes.
Response:
17. Was response correct?
If YES, then continue with Step 18.
If NO, then do Trouble Clearing: TAP-116.
18. Did the letter "C" appear in the FE ID display?
If NO, then proceed to Step 33.
If YES, then proceed to Step 23.
ABN LED lights on User Panel and a "P" is displayed in
SYSCTL FE ID display in the shelf receiving the program.
PC starts download and prints the following message:
Searching for optimal transfer rate.
Handshake established at <baudrate> baud.
In progress . . . .
The dots continue to print until program installation is
complete. If floppy disks are being used, insert each
diskette when prompted. After installation is completed,
the PC prints the following completion message:
ins-prog:TID COMPLD
/* Generic a.b.c is installed */
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER