363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
2.
NOTE:
The rtrv-eqpt: command retrieves the Equipage and
Version Report. This report lists the circuit pack type
and version information for one or more slots. See the
Commands and Reports section of this manual for a
description of the rtrv-eqpt: command format.
Use the rtrv-eqpt: command to obtain the Equipage and
Version Report and verify that the service and protection (if
required) STS1E circuit packs have been installed in the proper
FUNCTION UNITS group (A, B, or C) being put into service.
3.
NOTE:
The rtrv-ec1: command retrieves the EC1 Port
Provisioning Report. This report lists information
about each EC-1 port. This information includes attributes
set by the set-ec1: command and parameters set by
switches on the circuit pack. See the Commands and
Reports section of this manual for a description of the
rtrv-ec1: command format.
Use the rtrv-ec1: command to obtain the EC1 Port
Provisioning Report and verify the hardware and software
option settings.
4.
NOTE:
DS1/DS1PM circuit packs cannot be installed in a shelf
group equipped with STS1E circuit packs optioned for LOW
SPEED mode.
Verify/set line build out (LBO) option jumpers on STS1E circuit
pack(s), as required.
5.
NOTE:
If the option switch setting is changed, an update must be
done by momentarily depressing the UPD/INIT button on the
SYSCTL circuit pack after the STS1E circuit pack is
reinstalled.
If necessary, set the STS1E circuit pack option switch to LOW
SPEED and reinstall the STS1E circuit pack(s).
DDM-2000 OC-3 M
System Turnup:
ULTIPLEXER
NTP-034
Page 2 of 6
DLP-513
DLP-513