NTP-058
: Circuit Order
Page 3 of 6
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
2.
Use rtrv-map-network: and rtrv-map-neighbor:
commands to verify the configuration of the OC-3 ring being
upgraded and how the individual nodes are connected.
3.
Upgrade all nodes to OC-3 TARP Release 15 software, if
required.
A.
In-Service Local Software Download
B.
In-Service Remote Software Download
4.
It is recommended that the TL1/X.25 link at the network's GNE
node be disabled during this upgrade by disconnecting the cable
connected to J45 on the rear of the shelf at the GNE node.
5.
Use the rtrv-ne command at each node in the network to
determine if the RneStat parameter is enabled. If it is, disable it at
each node using the set-ne command. It must remain disabled
until this upgrade is completed.
!
CAUTION:
Sync autoconfiguration must be enabled at each line-timed node in the network.
6.
At each line-timed node in the network, use
set-oc12:syncmsg=Kbyte/Sbyte command to set Kbyte or
Sbyte sync messages. Use set-sync:auto=enabled
command to enable Sync auto-reconfiguration.
7.
Enter the init-pm:reg=all command.
8.
Wait 20 seconds.
9.
Enter the rtrv-pm-line:main-all command. The current
time line in the response should indicate that there are no errors.
DDM-2000 OC-3 M
Issue 3, June 2001
ULTIPLEXER
363-206-285
DLP-532
DLP-562