DLP-532
: Detailed Level Procedure
Page 7 of 14
8.
Did the letter "C" appear in the FE ID display?
If NO, then STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If YES, then proceed to Step 23.
FE ID Display Blank
9.
NOTE:
If PC hard drive is being used, ensure you are in the correct directory. If
floppies are being used, ensure the first (number 1) diskette is installed in
floppy drive.
Enter term or term COMn command, where n = 1 or 2. If term is entered
without the COMn option, then COM1 will be selected by default. Disregard
message Can't find script <init> if you see it after starting the
terminal emulator.
Response:
10.
NOTE:
The default shelf is the shelf physically connected to the PC. To set baud
rate automatically, enter two carriage returns (<cr>), two lower case "a"s
(aa), or two upper case "A"s (AA). All other characters are ignored.
Enter two carriage returns.
Response:
11. Was response correct?
If YES, then continue with Step 12.
If NO, then proceed to Step 28.
Two brief messages are printed and you are instructed to
Press any key to continue . . . after the second
message. After you press any key, the terminal emulator
is loaded and the terminal responds as follows:
CTRM ready. (Type Alt-h for help.)
Communications established.
PC prompts with:
/* Enter a shelf number from 1 to 8 */
shelf [default] =
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285