: System Turnup
Page 6 of 10
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
13.
NOTE:
A maximum of three BBF8 HDSL circuit packs, including a
protection circuit pack, can be installed in any one function
group. Both service and protection MXRVO circuit packs
must also be installed.
Install BBF8 HDSL circuit packs (if required).
14.
NOTE:
Both service and protection MXRVO circuit packs must be
installed in FUNCTION UNITS groups corresponding to
LOW SPEED GROUP(s) equipped with T1EXT circuit packs.
Install T1EXT circuit pack(s) (if required).
15. Install BBF9/BBF10 IMA LAN circuit packs (if required).
16.
!
CAUTION:
The command init-sys:all may affect service. It should
never be used on an in-service system. It should be used
only after a shelf has been equipped to reset all
provisionable parameters and cross-connections to their
default values.
NOTE:
An inconsistent DCC values alarm will occur when the
init-sys:all command is executed because "fecom"
becomes enabled again. To clear the alarm, use the
set-fecom:address:com=disable to disable the DCC.
Use the init-sys:all command to initialize all provisionable
parameters to their original default values. It may take
approximately 2 minutes after init-sys:all command for
alarms to stabilize.
17. Perform an LED test.
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285
DLP-564
DLP-517
DLP-518
DLP-509