Lucent DDM-2000 OC-3 User And Service Manual page 939

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
NOTE:
The software to be remotely copied is a non-executing, dormant copy of
the IMA LAN software generic.The apply command is used later to
overwrite the currently executing generic in the addressed IMA LAN
circuit pack(s) with a copy of the generic included in the dormant
software.
NOTE:
Starting with OC-3 Release 15.0, if an apply command is issued, the
user will be prompted for Program Type with a value of either nesw (for
NE software generic) or lansw (for IMA LAN software generic).
7.
Are you using ins-prog: or cpy-prog: command to download software to
far-end shelf?
If CPY-PROG, then continue with Step 8.
If INS-PROG, then proceed to Step 16.
!
8.
CAUTION:
Only one cpy-prog: procedure at a time should be performed in the
same maintenance subnetwork. Simultaneous cpy-prog: procedures
in the same network may fail.
Connect and establish session with local shelf being used as a source for the
new remote program download.
Reference: DLP-521
9.
Use rtrv-map-network command to retrieve the tid of the shelf having
the new program installed.
10.
NOTE:
If the cpy-prog: command is denied for any reason, the reader should
reference the command documentation, so that the appropriate actions
are taken.
DDM-2000 OC-3 M
Detailed Level Procedure:
ULTIPLEXER
DLP-528
Page 3 of 12

Advertisement

Table of Contents
loading

Table of Contents