363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
NOTE:
If the DS1 terminating end(s) are in a DDM-2000 OC-3, this
procedure assumes that MXRVO circuit packs have already
been installed during initial shelf turnup and TMUX circuit
packs have been installed during initial shelf turnup at the
other DDM-2000 OC-3 terminating end(s) of the circuit. If the
terminating end is in another system, it is assumed that the
appropriate installation and connections have been made to
that system. If the appropriate circuit packs have not been
installed and the system is in service on other groups, refer
to System Turnup/Circuit Order: IXL-001 for procedures to
add a new group for DS1 service.
NOTE:
If the DDM-2000 fails to respond in the indicated manner,
refer to Trouble Clearing: IXL-001.
Verify that no LEDs or alarms are activated. If any LEDs or alarms
are activated, refer to Trouble Clearing: IXL-001 and follow the
appropriate trouble-clearing procedure.
2.
At the DS3 terminating node(s) of the circuit being established,
determine which DS3 port is to be put into service and what
options are to be selected.
3.
NOTE:
The rtrv-eqpt:command retrieves the Equipage and
Version Report. This report lists the circuit pack type
and version information for one or more slots. See the
Commands and Reports section of this manual for a
description of the rtrv-eqpt: command format.
Use the rtrv-eqpt: command to obtain the Equipage and
Version Report and verify that the service and protection (if
required) TMUX circuit packs have been installed in the proper
FUNCTION UNITS group (A, B, or C) being put into service.
At the DS1 terminating end, use the rtrv-eqpt: command to
obtain the Equipage and Version Report and verify that the
proper service and protection (if required) MXRVO (STS1E) circuit
packs have been installed in FUNCTION UNITS group(s) (A, B, or
C) being put into service.
DDM-2000 OC-3 M
System Turnup:
ULTIPLEXER
NTP-020
Page 2 of 8