Lucent DDM-2000 OC-3 User And Service Manual page 838

Tarp release 13 and later volume ii
Table of Contents

Advertisement

DLP-513
: Detailed Level Procedure
Page 18 of 20
BBF6 T1EXT
31. Determine circuit pack option switch settings from office records or work order.
32.
NOTE:
DS1 line coding may be set using either the option switches OR the
set-t1: command. It is recommended that a policy be established to
set line coding using either the switches OR the command. If DS1 line
code (lc) parameters are set using the set-t1: command, a software
override will be active and the circuit pack switch settings will have no
effect. The software override will remain active until the set-t1:
command is executed again and the noOverride option is selected.
The rtrv-t1: command may be used to check line code settings.
Refer to Table N and Figure 9 and set the line code option switches, if
required.
33. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
Table N – T1 Line Code Settings
Line Code
Format
B8ZS
AMI
Note: Switch 1, section 3 (S1-3), section 4 (S1-4), and section 5 (S1-5) are
unused and must be set to OFF.
Edge
Connector
Switch S1 Settings
S1-1
S1-2
(Port 1)
(Port 2)
OFF
OFF
ON
ON
Component Side
Figure 9 – BBF6 T1EXT Option Settings
DDM-2000 OC-3 M
Issue 2, February 2000
S1-3
S1-4
(Unused)
(Unused)
OFF
OFF
S1
ULTIPLEXER
363-206-285
S1-5
(Unused)
OFF
ON
1
2
3
4
5
OFF