Lucent DDM-2000 OC-3 User And Service Manual page 608

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
/* Active Alarms and Status Report
=============================================================
Alarm
Source
Level
Address
=============================================================
CRITICAL
main-2
-------------------------------------------------------------
MAJOR
m2-2-1-1
MAJOR
dcc-m2
MAJOR
dcc-m1
-------------------------------------------------------------
MINOR
main-1
-------------------------------------------------------------
ne-acty
-
*/
Figure 1 – Example of Active Alarms and Status Report
3.
NOTE:
Local alarm or status conditions have a Source Address of the local
slot, line, port, channel, path, cross-connection, or operations interface
(DCC, X.25, etc.) where the event occurred. (See Addresses in the
Commands and Reports section of this manual.) Use the rtrv-alm:
command to get another report, if necessary.
Note the local trouble indication in the Description column of the Active
Alarm and Status Report, starting with the highest alarm level (Critical)
listed in the Alarm Level column.
4.
Use opr-aco; command to silence active audible office alarms, if required.
5.
Find the trouble description in Table A for the highest alarm level and go to the
indicated step or procedure.
Date
Time
Srv
Detected
MM-DD HH:MM:SS
SA
MM-DD HH:MM:SS
.
.
.
MM-DD HH:MM:SS
MM-DD HH:MM:SS
MM-DD HH:MM:SS
DDM-2000 OC-3 M
Trouble Clearing:
Description
inc. OC3 LOS
inc. VT AIS
section DCC chan fail
section DCC chan fail
inc. OC3 LOS
holdover mode active
ULTIPLEXER
TAP-101
Page 2 of 10

Advertisement

Table of Contents
loading

Table of Contents