Lucent DDM-2000 OC-3 User And Service Manual page 229

Tarp release 13 and later volume ii
Table of Contents

Advertisement

NTP-024
: Circuit Order
Page 13 of 24
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
39. Connect optical fibers from CO OC-3 shelf MAIN 2(P) OLIU to
OC-12 FN-( )-2(P) OLIU being used for OC-3 extension.
40. At the starting node (Node 1), Remove optical fibers from OC-3
shelf MAIN 1 OLIU.
41. At starting OC-3 node, install a 24/29-Type OLIU into MAIN 1
OLIU slot and reconnect optical fibers.
42. At the starting node, connect the OC-12 faceplate connector
between MAIN 1 and MAIN 2(P) 24/29-Type OLIUs. Wait until
OC12 connector failed alarm clears.
!
43.
CAUTION:
The update (upd) command must be executed at the Node
with both 24/29-Type OLIU s installed.
NOTE:
After the update at this node, the inc. OC-12 LOF alarm
remains until the 24/29-Type OLIU is installed at the
connecting Node.
Momentarily depress the UPD button on the SYSCTL or execute
the update (upd) command at the Node with both 24/29-Type
OLIUs installed.
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285