363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
11. Perform optical fiber connections and verification of the integrity of
the optical span being established.
12.
NOTE:
Shelves that are part of a subnetwork being partitioned into
multiple areas require that the NSAPAREA field and level 2
IS-IS routing parameters of the ent-ulsdcc-l3:
command be set. See Section 11, Commands and Reports
in 363-206-285, DDM-2000 OC-3 Multiplexer, TARP
Release 13 and Later, User/Service Manual —Volume I and
363-206-305, DDM-2000 FiberReach Multiplexer,
Wideband/Narrowband Shelf, TARP Release 3 and Later,
User/Service Manual , for an explanation of the command
parameters and 824-102-144, Lucent Technologies 2000
Product Family, Operations Interworking Guide For TARP
Releases , for an explanation of the engineering rules for
subnetwork partitioning.
Use the ent-ulsdcc-l3: command to designate the
NSAPAREA field and level 2 IS-IS routing, as required.
13.
NOTE:
The rtrv-pm-line: command in the following procedure
displays performance monitoring data associated with the
OC-1 lines terminated on the system.
Perform end-to-end OC-1 line test.
14. Repeat this procedure for all OC-1 optical spans back to the host
OC-3 shelf.
15. The system is now ready for initial service to be established.
Initial DS1 Service [System Turnup: NTP-004]
DDM-2000 OC-3 M
System Turnup:
ULTIPLEXER
NTP-045
Page 5 of 8
DLP-514
DLP-556