Lucent DDM-2000 OC-3 User And Service Manual page 371

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
54. Reinstall all TGS/TG3 circuit packs in TIMING slot 1, if still
removed.
55.
NOTE:
If Kbyte or Sbyte (sync messaging) is enabled for the
main-1 and main-2 optical interfaces at any node in a ring,
it must be enabled at all nodes of the ring.
NOTE:
The rtrv-oc3: command retrieves the
OC-3 Line Provisioning Report. This report displays
the provisioned configuration of OC-3 lines. See the
Commands and Reports section of this manual for a
description of the rtrv-oc3: command format.
Use the rtrv-oc3: command to obtain the
OC-3 Line Provisioning Report and verify if Kbyte/Sbyte
is enabled or disabled. Use the set-oc3: command to enable or
disable the Kbyte/Sbyte parameter, as required.
DDM-2000 OC-3 M
Circuit Order:
ULTIPLEXER
NTP-039