Lucent DDM-2000 OC-3 User And Service Manual page 937

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
Install New IMA LAN Software Generic Program
1.
Before beginning the software installation, refer to the Software Installation
and Upgrade Procedure section of the Software Release Description. This
section contains a description of any special considerations required when
installing this version of software.
NOTE:
2.
This procedure uses the cpy-prog: or ins-prog: commands to install
a new software program in a remote in-service DDM-2000 OC-3 shelf. It
is assumed that the local shelf has already been upgraded and the
software is running normally or has been installed as a dormant copy. For
procedures to download software locally to a shelf, see DLP-525.
NOTE:
Starting with OC-3 Release 15.0, if a cpy-prog: or ins-prog:
command is issued; in addition to the TID, the user will be prompted for
Program Type with a value of either nesw (for NE software generic) or
lansw (for IMA LAN software generic).
NOTE:
The new command format for cpy-prog: is
cpy-prog:tid,pgmtype=lansw; and for ins-prog is
ins-prog:tid,pgmtype=lansw; where the TID entered is that of the
remote shelf where you want to install the new software.
Verify that no DCC failures or transmission failures (OC-3 LOS, flashing OLIU
FAULT LEDs, etc.) are present on the network element or system receiving the
program.
3.
Use rtrv-fecom/set-fecom command to verify/enable far-end
communications (fecom).
In-Service System
Remote Shelf Download
DDM-2000 OC-3 M
Detailed Level Procedure:
ULTIPLEXER
DLP-528
Page 1 of 12