NTP-043
: System Turnup
Page 5 of 8
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
13.
NOTE:
Shelves that are part of a subnetwork being partitioned into
multiple areas require that the NSAPAREA field and level 2
IS-IS routing parameters of the ent-ulsdcc-l3 command
be set. See Section 11, Commands and Reports in
363-206-285, DDM-2000 OC-3 Multiplexer, TARP Release
13, User/Service Manual—Volume I and 363-206-305,
DDM-2000 FiberReach Multiplexer, Wideband/Narrowband
Shelf, TARP Release 3 and Later, User/Service Manual , for
an explanation of the command parameters and
824-102-144, Lucent Technologies 2000 Product Family,
Multi-Vendor Operations Interworking Guide , for an
explanation of the engineering rules for subnetwork
partitioning.
Use the ent-ulsdcc-l3 command to designate the NSAPAREA
field and level 2 IS-IS routing, as required.
14.
NOTE:
The rtrv-pm-line command in the following procedure
displays performance monitoring data associated with the
OC-1 lines terminated on the system.
Perform end-to-end OC-1 line test.
15. Repeat this procedure from Step 10 for all OC-1 optical spans
back to the host OC-3 shelf.
16. The single-homed FiberReach access network is now ready for
initial service to be established.