Lucent DDM-2000 OC-3 User And Service Manual page 825

Tarp release 13 and later volume ii
Table of Contents

Advertisement

363-206-285
Issue 2, February 2000
8.
NOTE:
Switches S1-1 and S1-2 are ignored by the system the first time the TGS
is installed unless the timing mode is set to DS1 External . Subsequent
removal or replacement of the TGS requires that switches S1-1 and S1-2
be set the same as the original settings or an update (upd) command
must be performed.
Is timing mode set to DS1 External ?
If YES, then continue with Step 11.
If NO, STOP. YOU HAVE COMPLETED THIS PROCEDURE.
9.
Refer to Table D and Figure 2 and set the DS1 line coding and frame format as
required for the TGS circuit pack.
Table D – BBF2 TGS DS1 Line Coding and Frame Format Switch Settings
DS1 Line Code
AMI
B8ZS
10. STOP. YOU HAVE COMPLETED THIS PROCEDURE.
Figure 2 – BBF2 TGS Option Switch
Switch
S1-1
DS1 Frame Format
ON
SF
OFF
ESF
DDM-2000 OC-3 M
Detailed Level Procedure:
Switch
S1-2
ON
OFF
ULTIPLEXER
DLP-513
Page 5 of 20