363-206-285
Issue 2, February 2000
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
29.
NOTE:
DDM-2000 shelves that are part of a subnetwork being
partitioned into multiple areas require that the NSAPAREA
field and level 2 IS-IS routing parameters of the
ent-ulsdcc-l3: command be set. See Section 11,
Commands and Reports in 363-206-285, DDM-2000 OC-3
Multiplexer, TARP Release 13 and Later, User/Service
Manual—Volume I , for an explanation of the command
parameters. FT-2000 shelves that are part of a subnetwork
being partitioned into multiple areas require that the L3 Area
Address and Level 2 IS parameters of the
CONFIGURATION-Set-ULSDCC-L3 command be set. See
365-575-103, FT-2000 OC-48 Lightwave System, Release
8.1 Through 9.1, User/Service Manual , for an explanation of
the command parameters. See 824-102-144, Lucent
Technologies 2000 Product Family, Operations Interworking
Guide For TARP Releases , for an explanation of the
engineering rules for subnetwork partitioning.
At the DDM-2000 shelf, use the ent-ulsdcc-l3: command to
designate the NSAPAREA field and level 2 IS-IS routing, as
required.
At the FT-2000 shelf, use the
CONFIGURATION-Set-ULSDCC-L3 command to designate the
L3 Area address and Level 2 IS parameters, as required.
30. Perform end-to-end OC-3/IS-3 line test at DRI nodes associated
with the FT-2000 primary node (for example, nodes B and C in
Figure 2).
31. At the OC-3 DRI node, use the ent-crs-sts1: or
ent-crs-vt1: commands to make proper "drop and continue"
cross-connections.
DDM-2000 OC-3 M
Circuit Order:
ULTIPLEXER
NTP-042
Page 8 of 12
DLP-515
DLP-550