363-206-285
Issue 3, June 2001
DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
5.
!
CAUTION:
The init-sys:all command should NOT be used on an
in-service system.
NOTE:
A craft interface terminal (CIT) is required to access the
optional features of the DDM-2000.
NOTE:
During installation and/or initial testing, provisionable
parameters may have been set which need to be reset to
their default values. STS1 and/or VT1.5 cross-connections
may have been made which should be deleted before the
system is placed in service. The init-sys:all command
may be used to reset all provisionable parameters and
cross-connections to default values.
NOTE:
An inconsistent DCC values alarm will occur when the
init-sys:all command is executed. To clear the alarm,
use the set-fecom:address:com=disable command to
disable the DCC.
If required, use the command init-sys:all to reset
provisionable parameters to default values.
6.
NOTE:
These procedures assume that the DDM-2000 has been
connected to the DSX-( ) cross-connect points, as required.
DS1 and/or DS3 circuit packs must be inserted, as required,
before performing these tests.
Perform transmission and cross-connect tests for each group, as
required. Refer any failures to organization that installed the
DDM-2000.
Ring Releases
A. DS1 Transmission/Cross-Connect Test
B. DS3 Transmission/Cross-Connect Test
DDM-2000 OC-3 M
Acceptance:
ULTIPLEXER
NTP-003
Page 3 of 4
DLP-510