DO ITEMS BELOW IN ORDER LISTED . . . . .FOR DETAILS, GO TO
12.
NOTE:
If Sync Autoreconfiguration is enabled, Kbyte/Sbyte must
also be enabled.
NOTE:
If Sync Autoreconfiguration is enabled at any line-timed
OC-3 or OC-12 node in a ring, it must be enabled at all
line-timed OC-3 or OC-12 nodes of a ring.
NOTE:
The rtrv-sync: command retrieves the
Synchronization Report. This report displays the
provisioning and operational information on the
synchronization attributes of the DDM-2000. See the
Commands and Reports section of this manual for a
description of the rtrv-sync: command format.
Use the rtrv-sync: command to obtain the
Synchronization Report and verify if Sync
Autoreconfiguration is enabled or disabled. Use the set-sync:
command to enable or disable the Sync Autoreconfiguration
parameter, as required.
13.
NOTE:
Two or more shelves in the same network cannot have the
same system name or TID (set by the set-ne: command).
Verify no duplicate TID settings exist. The rtrv-ne: command
may be used at each shelf in the network to display settings. If
duplicates exist, determine new settings and use the set-ne
command to make new settings.
14. What Release of software is installed in the system?
If Release 15 software is installed, continue with Step 15.
If Release 13 software is installed, proceed to Step 16.
DDM-2000 OC-3 M
System Turnup:
ULTIPLEXER