Lucent DDM-2000 OC-3 User And Service Manual page 439

Tarp release 13 and later volume ii
Table of Contents

Advertisement

NTP-047
: System Turnup
Page 3 of 12
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
7.
What Release of software is installed in the system?
If Release 15 software is installed, continue with Step 8.
If Release 13 software is installed, proceed to Step 9.
8.
Use the rtrv-oc3/set-oc3 or rtrv-oc12/set-oc12
command at the remote DDM-2000 OC-3 shelf to verify/set
application (dcc) parameter for the OC-3/OC-12 MAIN slots being
used for this OC-3/OC-12 linear extension. For example,
set-oc3:main-1,dcc=distinct and
set-oc3:main-2,dcc=distinct or
set-oc12:main-1,dcc=distinct and
set-oc12:main-2,dcc=distinct.
9.
NOTE:
This procedure will establish the OC-3 or OC-12 ring
configuration starting from the FT-2000 host node (far end)
to the first OC-3 or OC-12 node (near end), then continuing
to the next OC-3 or OC-12 node until the final connection is
made from the last OC-3 or OC-12 node back to the host
FT-2000 node.
NOTE:
The Network Side (NS)/User Side (US) parameters of the
OC-3 or OC-12 set-fecom: command and the FT-2000
DCC orientation must be set opposite at each end of the
optical spans. For example, see Figures 2 and 3.
Use the rtrv-fecom/set-fecom command at the DDM-2000
or the CONFIGURATION-Enter-Assignment-DCC command at
the FT-2000 to verify/set Network Side/User Side parameters at
each end of all optical spans being established.
DDM-2000 OC-3 M
Issue 2, February 2000
ULTIPLEXER
363-206-285