Table A – Minor Alarm Conditions
Alarm Level or
LED Indication
Trouble Description (Note)
MN LED lighted.
2nd CP required for
BBF3/BBF8
2nd CP required for
BBF6/BBF9
–48V power/fuse FA|FB failed –48V power feeder or fuse on
automatic protection switch
(APS) channel failed
automatic protection switch
(APS) automatic lock
CP not allowed - (crs)
CP not allowed - (eqpt)
CP not allowed - (timing)
See notes/footnotes at the end of this table.
DDM-2000 OC-3 M
Issue 2, February 2000
Likely causes
The BBF3/BBF3B DS1PM or
BBF8 HDSL CPs require both
FUNCTION UNITS slots in the
group to be equipped with
MXRVO or STS1E CPs.
The BBF6 T1EXT or BBF9
IMA LAN CPs require both
FUNCTION UNITS slots in the
group to be equipped with
MXRVO CPs.
User Panel failed.
Failure of near-end or far-end
protection OLIU CP in MAIN-2(P)
slot or failure of receive fiber on
the protection line at near end.
Four automatic switches of one
DS1/DS1PM CP in 10 minutes;
DS1 intermittent failure.
CP does not support the manual
cross-connection(s) currently
provisioned for this slot.
A DS1 or DS1PM CP is installed
in a LOW SPEED slot associated
with FUNCTION UNITS slot
provisioned for DS3, STS1E_L
low speed, or OLIU CP service.
When associated with TGS/TG3
slot, current CP switch settings do
not support the sync. timing
provisioned.
When associated with FUNCTION
UNITS slot C, CP type does not
support the current provisioned
sync. parameters.
ULTIPLEXER
363-206-285
Step or Procedure
Insert a second
MXRVO or STS1E
CP in the
companion
FUNCTION UNITS
slot.
Insert a second
MXRVO CP in the
companion
FUNCTION UNITS
slot.
Check –48V power
feeders or replace
fuse.
[DLP-555]
TAP-111
Replace
DS1/DS1PM CP.
[DLP-523]
Change CP or
change
cross-connections
Remove
DS1/DS1PM CP or
change FUNCTION
UNITS slot to
MXRVO or STS1E-H
high speed CP.
Change TGS/TG3
CP switches
[DLP-513] or change
sync. parameters
(
)
.
set-sync:
Change circuit pack
type or change
timing options